ABOUT THIS EPISODE
Episode Summary
A client sent Mikki a link to a very flash Withings bioelectrical impedance scale — NZ$819, marketed as 99% as accurate as a DEXA scan — and asked the obvious question: is it worth the money? In this solo episode Mikki goes and reads the validation document behind that claim, and finds the problem isn't really the scale at all. It's a statistical sleight of hand that turns up constantly in health tech marketing: reporting a correlation and calling it accuracy.
Mikki explains the difference in plain terms, with a worked example where a scale reads exactly half the true value every single time and still produces a perfect correlation of 1.0. She then sets the company's own document against three pieces of independent research — a January 2026 systematic review of BIA against a four-compartment model, Siedler and colleagues' 2023 comparison of fifteen BIA devices, and a June 2026 study putting the InBody H20N up against DEXA — to show what honest reporting of a body composition device actually looks like. She finishes with the four readouts on these scales that aren't worth your attention, a practical protocol for getting genuine information out of the one you already own, and four questions worth asking of any health tech accuracy claim you meet in the next few years.
Key Topics
- Correlation is not accuracy. The 99% claim rests on a correlation of 0.99 for total fat mass across 80 people. Mikki accepts the correlation is real, and shows with a worked example why it says nothing about whether any individual reading is right.
- What you actually want is agreement. Mean difference and limits of agreement, via a Bland-Altman analysis — the standard approach since the mid-1980s, and one the company's document didn't use.
- What the validation document left out: mean difference from DEXA, limits of agreement, individual prediction error, the age and sex breakdown, the body fat range, whether hydration and fasting were standardised, and whether the validation sample was independent of the data used to build the algorithm. Mikki could find no peer-reviewed publication of it, and notes total body water was validated against a different device entirely.
- Better hardware doesn't settle the evidence question. Mikki is clear the Withings unit is well built — eight electrodes including a handheld bar, multiple frequencies, current through arms, trunk and legs rather than up one leg and down the other. That is a separate question from whether the accuracy claim stands up.
- The independent evidence. A January 2026 systematic review of 12 studies found mean bias for body fat percentage ranging from 3.5 percentage points too low to 4.4 too high, with limits of agreement typically spanning 15 to 20 percentage points, and concluded BIA was not equivalent to the four-compartment reference.
- Reliable does not mean accurate. Across 15 devices, precision error was 0 to 0.5 percentage points — these scales are very consistent with themselves. A device can be reliably wrong, which is why direction of change can still be informative even when the absolute number isn't. The longitudinal results were more mixed: some devices tracked change reasonably, others didn't.
- What honest reporting looks like. In 55 adults with obesity, the InBody H20N sat 1.64 percentage points from DEXA on body fat, with limits of agreement of −3.4 to +6.7 — good across a group, much looser for the individual standing on it. Skeletal muscle mass was worse, overestimated by 5.66 kg on average. Less impressive than 99%, and far more useful.
- Four readouts not worth watching: visceral fat (a proprietary index on an arbitrary scale, not a measurement of visceral adipose tissue like CT or MRI); bone mass (not bone mineral density, and no guide to osteoporosis risk — DEXA is the answer there); basal metabolic rate (calculated from an equation, not measured — that needs indirect calorimetry); and body water (better on a multi-frequency device, still modelled).
- How to use the scale you have. Standardise everything you can control, because hydration, glycogen and cycle phase move these numbers more than real change does over a short window. Measure three or four times a week, average weekly, read four-week trends, and triangulate against weight, waist, clothing fit, training numbers and photos. Swap "my body fat is 23.7%" for "my body fat estimate has trended down over the last 10 weeks".
- The transferable point. InBody's own product page claims over 98% agreement with DEXA — near enough the same move. When you're told a number is 99% accurate, ask what that means, what it was compared against, who paid for the comparison, and how far off an individual reading can be.
Chapters
00:00 The $819 scale and the 99% claim
02:15 Why correlation is not accuracy
04:27 Better hardware, missing evidence
06:48 What the independent research shows
09:10 InBody versus DEXA: the real numbers
11:53 Readouts not worth watching
13:27 How to use a scale well
15:40 Questions to ask of health tech
Guest / Resources
This is a solo episode — no guest.
Studies discussed
- The Validity of Bioelectrical Impedance Analysis Compared to a Four-Compartment Model in Healthy Adults: A Systematic Review — Journal of Functional Morphology and Kinesiology, 31 January 2026. Twelve studies; mean bias for body fat percentage −3.5 to +4.4 percentage points; limits of agreement typically 15–20 percentage points. https://doi.org/10.3390/jfmk11010065
- Siedler MR et al. Assessing the reliability and cross-sectional and longitudinal validity of fifteen bioelectrical impedance analysis devices — British Journal of Nutrition, 2023;130:827–840. Seventy-three adults across 15 BIA devices against a four-compartment model, with 37 returning 12–16 weeks later for the longitudinal analysis.
- Ellison KM, Gard W, Wood J, Layton C, Sayer RD. Assessing Body Composition for Resource-Limited Settings: Agreement of a Scalable BIA Device Compared to DXA and Clinical BIA in Adults With Obesity — Journal of Primary Care and Community Health, 2026. The InBody H20N against DEXA in 55 adults with obesity (mean age 62.6, 67% female), under an 8-hour fast with no alcohol or vigorous exercise for 24 hours. The research group is at the University of Alabama at Birmingham. https://doi.org/10.1177/21501319261459756
Methods and terms mentioned
- Bland-Altman analysis — the standard method for comparing two measurement techniques, giving mean difference and limits of agreement
- Four-compartment model — a stronger reference than DEXA alone, accounting for body volume, total body water, bone mineral and body mass separately
- DEXA — the reference method throughout, and the gold standard for bone mineral density
- Indirect calorimetry — what measuring basal metabolic rate actually requires, using a mask and a metabolic cart
- CT and MRI — what an actual measurement of visceral adipose tissue requires
Devices mentioned
- Withings bioelectrical impedance scale — the NZ$819 device that prompted the episode
- InBody H20N — the consumer-grade portable device in the June 2026 study, AU$529, with no New Zealand retailer found at the time of recording
Related Mikkipedia episode
- Prof Gr...
IN THIS EPISODE
SHOW NOTES 🔗
TRANSCRIPT 🔗
00:00.000 --> 00:06.160
Hey everyone, it's Mikki here. You're listening to Mini-Mikkipedia on a Monday.
00:06.520 --> 00:13.960
Before I go on, if you like these episodes, or just Mikkipedia in general, can you subscribe
00:13.960 --> 00:19.040
on your favourite podcast listening platform, share it with a friend, because that then
00:19.040 --> 00:24.200
increases the visibility of Mikkipedia in amongst literally thousands of other podcasts out there.
00:24.520 --> 00:29.560
And if you feel so inclined, give me a five-star review. That would be amazing.
00:30.000 --> 00:35.200
All right, what are we talking about this week on Mini-Mikkipedia? I got sent an email from one
00:35.200 --> 00:41.500
of my clients, and she had a link to a very flash Withings scale. And I'm like, oh, this is
00:41.500 --> 00:49.180
interesting. And oh my goodness, it's 819 New Zealand dollars. JB high five. And it is a,
00:49.660 --> 00:57.220
essentially, it's a bioelectrical impedance scale, but apparently it's like 99% accurate.
00:57.220 --> 00:59.740
And I'm like, really? This sounds super interesting.
00:59.740 --> 01:04.140
And basically, my client was like, Mikki, is this worth the money? Because she's in the market
01:04.140 --> 01:09.980
for something that's actually worth its salt. And she says, I know that my usual scales just track
01:09.980 --> 01:15.540
kilograms, but I get a DEXA every year, but I'm still curious as to whether anything on the market
01:15.540 --> 01:22.680
right now is actually going to give me more information than that. And so that 99% as
01:22.680 --> 01:29.500
accurate as a DEXA as marketed was like, oh, that's super interesting. And with that price tag, I'm like,
01:29.740 --> 01:36.080
really? So I understand why that is appealing. Clearly, if you've ever paid for a DEXA scan,
01:36.520 --> 01:40.900
you know, it's not cheap. Well, you know, a few hundred bucks, at least you have to book it,
01:41.140 --> 01:46.480
you have to drive there, and you get one number on one day, whereas a scale in your bathroom,
01:47.100 --> 01:51.920
if that gave you that same information every morning for the price of like three scans or
01:51.920 --> 01:58.000
whatever, pretty appealing. So I went to read the research that the company links to. So I want to
01:58.000 --> 01:59.720
walk through what I found. And I'm like, oh, this is really, really, really, really, really, really,
01:59.740 --> 01:59.940
really, really, really, really, really, really, really, really, really, really, really, really,
01:59.940 --> 02:06.000
because the problem here isn't really about just one scale. It's about a statistical issue that
02:06.000 --> 02:11.000
shows up constantly in health tech marketing. And it's worth you knowing if you're at all
02:11.000 --> 02:15.660
interested in this. And for what it's worth, people always ask me about these BIA machines.
02:15.660 --> 02:24.440
So the claim that the Withings scales was 99% as accurate as a DEXA rests on this validation
02:24.440 --> 02:29.640
document that the company had produced. There were 80 people, each of them had one DEXA
02:29.640 --> 02:35.660
scan and three measurements on the scale. And the headline result was a correlation of 0.99 for
02:35.660 --> 02:42.180
total fat mass. Now 0.99 clearly is a very high correlation. And that part is clearly legit.
02:42.600 --> 02:48.760
But what isn't true is that correlation of 0.99 means that the scale is 99% accurate.
02:49.420 --> 02:54.780
A correlation tells you whether two things move together in the same direction. It tells you that
02:54.780 --> 02:59.200
people who have more fat mass on DEXA also have more fat mass on the scale.
02:59.640 --> 03:06.120
That's it. That is all that it tells you. So imagine three people. DEXA says they have 10,
03:06.120 --> 03:15.700
20, and 30 kilos of fat. The scale says 5, 10, and 15 kilos. Every single reading is wrong by one
03:15.700 --> 03:21.580
half. The scale has failed completely. But the correlation between these two sets of numbers
03:21.580 --> 03:29.380
is a perfect 1.0. It's exactly the same, yet doesn't really give you great data. And what you
03:29.640 --> 03:35.340
want when you're comparing two measurement methods is agreement, not correlation. You want
03:35.340 --> 03:40.400
to know the mean difference between the two. And you want the limits of agreement, which tell you
03:40.400 --> 03:45.480
how far off an individual person's reading is likely to be. And that's something called a
03:45.480 --> 03:52.560
bland Altman analysis. And it's been the standard way to do this since the mid-1980s. It actually
03:52.560 --> 03:57.360
isn't obscure. I mean, I'm just going to say right up front, I know next to nothing about this. I
03:57.360 --> 03:59.620
believe I used a bland Altman in one of my papers. I don't know if you've seen it. I don't know if
03:59.640 --> 04:04.120
it's actually from my thesis, but I cannot recall. But it's certainly not a niche statistical
04:04.120 --> 04:10.000
preference. It's the thing that you do. And they didn't do it. So I think this is always something
04:10.000 --> 04:15.040
interesting when you look at research and you know, or you learn that there is a particular
04:15.040 --> 04:21.780
statistical analysis that really suits a question. And it's completely ignored by the people doing
04:21.780 --> 04:27.800
the analysis. So that's worth noting. What I will say, however, I don't think the technology is
04:27.800 --> 04:29.600
rubbish at all, right? With that withings.
04:29.640 --> 04:30.100
So I think that's a good thing. And I think that's a good thing. And I think that's a good thing.
04:30.100 --> 04:30.260
So I think that's a good thing. And I think that's a good thing. And I think that's a good thing.
04:30.260 --> 04:36.140
This particular one uses eight electrodes, including a handheld bar, and it does run multiple
04:36.140 --> 04:41.300
frequencies. So that means the current passes through your arms, your trunk, and your legs,
04:41.580 --> 04:46.880
rather than just up one leg and down the other, which is what a cheap bathroom scale that I got
04:46.880 --> 04:52.380
at home does. So it is actually better hardware. But the evidence is a separate question from the
04:52.380 --> 04:57.920
hardware. So what I couldn't find anywhere in that material was the mean difference from the
04:57.920 --> 04:59.620
DEXA. The limits of a green screen are not as good as the green screen. So I think that's a good thing.
04:59.620 --> 05:05.100
That individual prediction error, the age and sex breakdown of the participants,
05:05.800 --> 05:11.540
the body fat range, whether hydration and fasting were standardized, as I've talked about with
05:11.540 --> 05:17.600
Professor Grant Tinsley on this podcast, who is a body composition expert, whether the validation
05:17.600 --> 05:22.400
sample was independent of the data used to build the prediction algorithm in the first place.
05:22.540 --> 05:27.080
And that does actually matter. And I couldn't actually find any peer reviewed publication
05:27.080 --> 05:29.440
of that study. Something else that's worth
05:29.440 --> 05:34.040
sort of chatting about is that the results are presented as though all four measures were
05:34.040 --> 05:40.000
validated against DEXA, but total body water, which is something else you can glean from
05:40.000 --> 05:45.900
these scales, was compared against an entirely different device. And I mean, of course, that
05:45.900 --> 05:52.200
makes sense because DEXA doesn't measure total body water. But it's worth noting that because
05:52.200 --> 05:56.240
it does tell you something about how carefully that document was put together. Basically,
05:56.240 --> 05:59.420
it's all marketing speak, and they're going to do as much as they can,
05:59.440 --> 06:06.800
to convince you of the accuracy and the utility of that scale. And then there was a line in it that
06:06.800 --> 06:12.500
says in the marketing that scale does not merely provide an estimate. I mean, it absolutely provides
06:12.500 --> 06:17.100
an estimate. That's all it's providing. This is what that technology does. The device measures
06:17.100 --> 06:23.320
your weight, and it measures electrical impedance. Everything else, your fat mass, your muscle mass,
06:23.320 --> 06:28.940
your visceral fat, your metabolic rate is calculated from those two inputs,
06:29.440 --> 06:36.360
plus your age, your sex, your height. It is run through this propriety algorithm. And the
06:36.360 --> 06:42.940
company's own technical explanation of the method tells you all of this, so that the entire thing
06:42.940 --> 06:48.620
is an absolute estimate. And then, you know, it is worth noting that there is good independent
06:48.620 --> 06:55.800
research on how accurate bioelectrical impedance actually is. And in January this year, there was
06:55.800 --> 06:59.420
a systematic review published in the Journal of Functional Morphology, which is a journal that
06:59.440 --> 07:07.020
looked at bio-impedance devices compared against a four-compartment model, which is stronger
07:07.020 --> 07:12.660
reference than a DEXA alone, because it accounts for body volume, total body water, bone mineral,
07:12.940 --> 07:19.400
and body mass separately. There were 12 studies, and across those studies, the mean bias for body
07:19.400 --> 07:26.000
fat percentage ranged from about three and a half percentage points, too low, to four and a half
07:26.000 --> 07:29.420
percentage points, too high. But the number I want you to look at is the number of studies that
07:29.420 --> 07:36.000
really think about is the limits of agreement, which typically spanned 15 to 20 percentage points.
07:36.180 --> 07:42.540
That's 15 to 20 percent. Wow. And the authors concluded that the BIA estimates of body fat
07:42.540 --> 07:47.780
percentage and fat-free mass were not equivalent to the reference model. And I mean, that does
07:47.780 --> 07:54.940
sound damning, and at the individual level it is, but there is a second finding that does make me
07:54.940 --> 07:59.100
think, you know, that may change how you should use these devices.
07:59.420 --> 08:07.560
So in a 2023 study in the British Journal of Nutrition, Seidler and colleagues put 73 adults
08:07.560 --> 08:14.820
through 15 different BIA devices and compared them all against a four-compartment model. 37 of those
08:14.820 --> 08:19.240
people came back 12 to 16 weeks later, so the researchers could look at whether the devices
08:19.240 --> 08:25.180
detected change accurately. The reliability was excellent. Precision error across the devices
08:25.180 --> 08:29.220
ranged from zero to about half a percentage point, which means that these
08:29.420 --> 08:36.620
devices are very consistent with themselves. So that is a key distinction. Reliable does not
08:36.620 --> 08:42.420
mean accurate. A device can be reliably wrong. If your scale reads three percentage points
08:42.420 --> 08:48.280
high every single time, your absolute number is wrong, but the direction and the size of the change
08:48.280 --> 08:53.580
might still be informative. The longitudinal results in that study I just mentioned were
08:53.580 --> 08:58.640
more mixed though. Constant error for detecting change ranged from about half a percentage point
08:59.420 --> 09:04.880
to just over one percentage point too high. So really it's telling you that some devices
09:04.880 --> 09:10.620
tracked change quite reasonably, but others really didn't. And in June of this year,
09:10.620 --> 09:15.580
there was a study published in the Journal of Primary Care and Community Health
09:15.580 --> 09:21.960
looking at the InBody H20N, which is a consumer-grade portable device
09:21.960 --> 09:28.940
against DEXA in 55 adults with obesity. Their average age was 62 and two-thirds of them were
09:28.940 --> 09:29.300
women.
09:29.420 --> 09:34.800
Participants fasted for eight hours, stayed hydrated, and avoided exercise and alcohol for
09:34.800 --> 09:39.660
24 hours beforehand, which is, you know, sort of gold standard practice, standardizing that stuff.
09:39.940 --> 09:45.580
For body fat percentage, the agreement with DEXA was excellent by the usual statistical standards.
09:46.120 --> 09:51.720
And they reported actual numbers. Mean difference of 1.64 percentage points,
09:51.720 --> 09:59.180
limits of agreement, minus 3.4 to plus 6.7 percentage points. So on average across
09:59.420 --> 10:05.360
the group, it's quite good. For an individual standing on it, the true value could plausibly be
10:05.360 --> 10:10.520
three and a half points below or nearly seven points above what the screen actually says.
10:10.880 --> 10:16.540
And for skeletal muscle mass, it was worse actually. The device overestimated by an average
10:16.540 --> 10:23.200
of 5.66 kilos. That's pretty huge compared to the DEXA with the limits of agreement spanning about
10:23.200 --> 10:29.340
10 kilos. So I mean, that's what proper reporting looks like. It's way less impressive than the
10:29.340 --> 10:29.400
90-day-old. But it's a good thing. It's a good thing. It's a good thing. It's a good thing. It's a good thing.
10:29.420 --> 10:36.240
But it's infinitely more useful because now you know how much you can actually trust that number.
10:36.900 --> 10:42.080
So two other things about that study. It was the first to compare that particular device,
10:42.200 --> 10:50.080
the InBody H2O-N against DEXA. And the authors did say that that longitudinal agreement,
10:50.360 --> 10:55.460
so whether it actually tracks change accurately over time, that hasn't been established.
10:55.720 --> 10:58.680
So that is a critical next research question.
10:58.680 --> 11:04.880
They do actually sell that machine, the H2O-N. As I said, it's a direct-to-consumer
11:04.880 --> 11:14.780
device. But InBody actually have a range of different devices, like the Dial H20,
11:15.300 --> 11:21.740
and then it's an H20B, and an H30, and an H40 in the same family. So these different models
11:21.740 --> 11:28.660
haven't been tested the way that the H, I called it the H20N, it's probably the H20B,
11:28.660 --> 11:35.800
has. So just note that, I think. And then if you look at how much it costs,
11:36.060 --> 11:40.640
like I started off this episode by telling you that the Wything scale was about 819 New Zealand
11:40.640 --> 11:47.820
dollars. The H20N InBody is 529 Australian dollars, but I couldn't find a New Zealand
11:47.820 --> 11:53.640
retailer actually stocking it. So it's cheaper than $800, but it's still not cheap.
11:53.640 --> 11:58.500
So here's something I just want you to bear in mind, regardless of what scale you,
11:58.660 --> 12:04.700
have. These are the metrics that generate pretty much a lot of attention, but are not worth paying
12:04.700 --> 12:11.120
attention to. The first one is visceral fat. On most of these devices, this is a propriety index
12:11.120 --> 12:15.880
on an arbitrary scale, meaning it's basically made up by the manufacturers, calculated from
12:15.880 --> 12:21.400
impedance, plus your age, sex, height, and weight. It is not a measurement of visceral adipose tissue
12:21.400 --> 12:26.840
in the way that a CT or MRI would give you. So don't treat a number going from nine to eight
12:26.840 --> 12:28.640
like it's something worth celebrating.
12:28.660 --> 12:34.180
Because really, it doesn't tell you anything. It's almost made up. Bone mass. This is not bone
12:34.180 --> 12:39.380
mineral density. Bioimpedance cannot tell you anything meaningful about your skeletal health
12:39.380 --> 12:46.260
or your osteoporosis risk. So if this is a concern of yours, then a DEXA scan is absolutely your best
12:46.260 --> 12:51.460
bet, because that is gold standard. Basal metabolic rate. This is calculated from an equation. It is
12:51.460 --> 12:56.980
not measured. Measuring it requires indirect colometry, which involves a mask and a metabolic
12:56.980 --> 12:58.480
card. And, you know, I don't want to go into too much detail about this, but I do want to
12:58.660 --> 12:59.200
know what you think about this. And I'm going to go into a little bit more detail about this.
12:59.200 --> 13:04.080
It basically will be derived, again, from an algorithm. And depending on the population that
13:04.080 --> 13:11.060
they derived it from, it's as accurate or otherwise as you would expect. So I just would
13:11.060 --> 13:17.120
not hang my hat on it. And body water. This is better informed on that multi-frequency device,
13:17.240 --> 13:21.780
like those eight different levers, than a cheap one. But it's still derived from an electrical
13:21.780 --> 13:27.780
model of your body fluids. So do I think you should throw your scale out? I mean, clearly not.
13:27.780 --> 13:28.640
I think you should throw it out. I think you should throw it out. I think you should throw it out.
13:28.660 --> 13:33.300
You should use it for what it's good at. So here's what I'd do. You want to standardize
13:33.300 --> 13:38.220
everything you can control. Same time of day, first thing in the morning, after you've been
13:38.220 --> 13:44.460
to the toilet, before food, fluid, or training. Hydration, glycogen, and even where you are in
13:44.460 --> 13:49.500
your cycle will move these numbers around. And they'll move them around more than a real change
13:49.500 --> 13:54.560
in body composition will over a short window. So there's a lot of noise. So you want to measure
13:54.560 --> 13:58.640
often. Three or four times a week is fine. Then average it across a week.
13:58.660 --> 14:06.300
Look at four-week trends, not daily readings. Your body fat estimate drops from 27.2 to 26.6.
14:06.600 --> 14:11.840
That's probably noise. But if it drifts consistently downward across two months of weekly averages,
14:12.080 --> 14:18.160
that's a signal. So that's a good thing. And then you want to triangulate. Don't just look at what
14:18.160 --> 14:22.420
your in-body tells you. Look at body weight, waist circumference, how your clothes fit,
14:22.820 --> 14:27.200
what's happening with your training numbers, photos if you find them useful. One measurement
14:27.200 --> 14:32.220
is a data point, but several measurements pointing in the same way. That's information.
14:32.820 --> 14:39.220
And then change that sentence you say to yourself of, you know, my body fat is 23.7%.
14:39.220 --> 14:46.220
Instead, think, my body fat estimate has trended down over the last 10 weeks. So that is much more
14:46.220 --> 14:51.880
accurate than that first sentence that I described. What I do want to be clear on is that, I mean,
14:51.880 --> 14:56.920
the Wything scale is as good as the in-body H20N. You know, like,
14:56.920 --> 15:01.900
I went in and read the in-body's own marketing after I read their study. And on their product
15:01.900 --> 15:07.300
page, they claim their technology has shown over 98% agreement with DEXA, which is pretty much
15:07.300 --> 15:15.060
exactly what the Wything scale said. So the entire category market correlation is accuracy because
15:15.060 --> 15:20.260
correlation coefficients are, they're pretty flattering, aren't they? But agreement statistics
15:20.260 --> 15:25.600
are not. And those are the ones that we want to be looking at. The only reason we know anything
15:25.600 --> 15:26.740
about that.
15:26.920 --> 15:30.400
In-body scale is that a research group in Alabama went and did the work themselves,
15:30.800 --> 15:35.260
published the limits of agreement and told us plainly that the device overestimates muscle
15:35.260 --> 15:39.540
by five and a half kilos. Obviously, a manufacturer is never going to put that on the box, right?
15:40.040 --> 15:45.980
And I guess, really, when it comes down to it, the point of this episode might not even be about
15:45.980 --> 15:51.860
those scales at all, right? When someone tells you a number is 99% accurate, ask what they mean.
15:52.320 --> 15:56.800
Ask what it was compared against, who paid for the comparison, and how far off an
15:56.800 --> 16:02.440
individual reading can be. Because those three questions will get you through most of this
16:02.440 --> 16:07.800
health tech that you'll be sold on in the coming years. And isn't there a lot of health tech these
16:07.800 --> 16:14.960
days? So I will say that, you know, a well-built consumer bioimpedance device can definitely be
16:14.960 --> 16:20.400
useful for tracking direction over months, but it's certainly not giving you 99% accuracy. But
16:20.400 --> 16:26.600
as long as you're aware about that, you triangulate that data, then I think you're good. If that is,
16:26.800 --> 16:32.260
you actually want to pay that $800 that these are selling for. Anyway, I'd love to hear whether
16:32.260 --> 16:37.200
you've got one of these machines, and you find it useful, or if you found this useful,
16:37.660 --> 16:42.340
hit me up. I'm over on Instagram, Threads and X, at Mikki Williden. I'm at Facebook,
16:42.340 --> 16:46.340
at Mikki Williden Nutrition, or head to my website, mikkiwilliden.com,
16:46.720 --> 16:52.720
and scroll right down to the bottom, pop your name in the box to jump on my email list.
16:52.960 --> 16:54.880
All right, guys, you have the best week. See you later.