전사 🔗
WEBVTT
00:00:12.970 --> 00:00:16.250
hello and welcome to catalyst conversations i'm
00:00:16.250 --> 00:00:19.469
your host lisa morrow today we're digging into
00:00:19.469 --> 00:00:22.030
a question that comes up on nearly every project
00:00:22.030 --> 00:00:24.629
and in countless conversations with architects
00:00:24.629 --> 00:00:27.989
and contractors is it better to choose kit doors
00:00:27.989 --> 00:00:31.469
or factory pre -hung doors in today's discussion
00:00:31.469 --> 00:00:34.570
we'll explore how each option affects performance
00:00:34.570 --> 00:00:38.549
consistency installation and why the right choice
00:00:38.549 --> 00:00:40.710
can make a measurable difference on the job site
00:00:41.390 --> 00:00:45.390
With me are Grace Jacob, IAC Acoustics Architectural
00:00:45.390 --> 00:00:48.250
Doors and Windows Sales Manager, and Mike Cerna
00:00:48.250 --> 00:00:51.189
of Hensel Diversified Construction, who's experienced
00:00:51.189 --> 00:00:53.670
at installing both types of doors in the field.
00:00:53.969 --> 00:00:57.829
Let's dive in. Grace, before we compare kits
00:00:57.829 --> 00:01:00.530
versus pre -hung doors, why don't you tell me
00:01:00.530 --> 00:01:03.369
what sets IAC Acoustics Architectural Acoustic
00:01:03.369 --> 00:01:08.569
Doors apart? Sure. I have two lines for doors.
00:01:08.790 --> 00:01:11.609
One is noise lock and the other is super noise
00:01:11.609 --> 00:01:16.549
lock. Super really just defines the size. So
00:01:16.549 --> 00:01:20.150
typically I can do a noise lock door up to 16
00:01:20.150 --> 00:01:24.069
by 16. We offer a wide range of veneer options
00:01:24.069 --> 00:01:27.849
to be stained and filled with those. STC 51 through
00:01:27.849 --> 00:01:31.290
64 assemblies and up to a three hour fire rating,
00:01:31.370 --> 00:01:34.909
but only 90 minutes with veneer. A super noise
00:01:34.909 --> 00:01:37.069
lock, on the other hand, is anything that swings
00:01:37.069 --> 00:01:41.230
over 16 by 16, anything vertical lift, and anything
00:01:41.230 --> 00:01:44.549
sliding or biparting. And those come in STCs
00:01:44.549 --> 00:01:48.689
51 and 55. We offer supplied and factory installed
00:01:48.689 --> 00:01:51.829
hardware to ensure proper fit, finish, and function
00:01:51.829 --> 00:01:54.310
in the field, as well as factory installed window
00:01:54.310 --> 00:01:57.250
options. These are fully factory assembled door
00:01:57.250 --> 00:01:59.569
sets that are pre -hung and swung before crating
00:01:59.569 --> 00:02:02.549
to ensure that they're going to align right in
00:02:02.549 --> 00:02:05.859
the field. Our not -so -secret sauce is the self
00:02:05.859 --> 00:02:08.680
-aligning magnetic seals. They ensure contact
00:02:08.680 --> 00:02:10.879
all around the door jamb to block any flanking
00:02:10.879 --> 00:02:17.000
paths. Awesome. Now, Mike, let's level set. Can
00:02:17.000 --> 00:02:18.879
you explain to our listeners what a kit door
00:02:18.879 --> 00:02:23.719
is? So, in my experience, a kit door is something
00:02:23.719 --> 00:02:28.379
that is basically what describes a kit. It comes,
00:02:28.560 --> 00:02:33.229
the frame is pre -assembled. But all of the seal
00:02:33.229 --> 00:02:37.229
beds, the hinges, the door leaf, all comes ready
00:02:37.229 --> 00:02:41.090
to assemble in the field. So what we do is we
00:02:41.090 --> 00:02:45.349
set the frame. We have to pin it in place. Then
00:02:45.349 --> 00:02:48.330
we apply the hinges to the leaf, apply the hinges
00:02:48.330 --> 00:02:51.430
to the frame, install the seal beds, install
00:02:51.430 --> 00:02:55.699
the seals in the seal beds. then hang the door
00:02:55.699 --> 00:02:58.099
and then we have to make critical adjustments
00:02:58.099 --> 00:03:00.900
to make sure that all of the seal beds some are
00:03:00.900 --> 00:03:03.900
magnetic some are just foam that they have a
00:03:03.900 --> 00:03:06.939
proper alignment so they get performance out
00:03:06.939 --> 00:03:09.360
of the door the other thing that the kit doors
00:03:09.360 --> 00:03:13.060
have is a foam seal that's their bottom sweep
00:03:13.060 --> 00:03:15.979
that traditionally needs to be cut to fit in
00:03:15.979 --> 00:03:19.960
the field which allows the possibility of misalignment
00:03:19.960 --> 00:03:23.460
or cutting cutting incorrectly we get one chance
00:03:23.460 --> 00:03:27.580
at it And it's a possibility that the door could
00:03:27.580 --> 00:03:30.639
underperform if that's not done correctly. So
00:03:30.639 --> 00:03:34.060
to be clear, Grace, doors from IAC come ready
00:03:34.060 --> 00:03:36.460
to install with all performance components integrated?
00:03:37.580 --> 00:03:40.300
Correct. So our doors show up fully assembled
00:03:40.300 --> 00:03:43.259
so that all the installers have to do is wait
00:03:43.259 --> 00:03:46.789
for it. install the door, and drop the bottom
00:03:46.789 --> 00:03:48.930
seal so it makes complete contact with the threshold.
00:03:49.530 --> 00:03:52.030
But the reason we factory install all the hardware
00:03:52.030 --> 00:03:54.650
is to control the quality and any variables.
00:03:55.050 --> 00:03:57.090
Once you start putting holes into a sound control
00:03:57.090 --> 00:03:59.689
door, you start playing with fire. These holes
00:03:59.689 --> 00:04:02.689
must be properly sealed to ensure acoustic performance.
00:04:03.090 --> 00:04:05.789
Plus, sound control doors are a little extra
00:04:05.789 --> 00:04:07.789
thick. They're the thick boys of the world, and
00:04:07.789 --> 00:04:10.349
so the hardware must be modified to bridge that
00:04:10.349 --> 00:04:14.759
whole gap, and we take care of all that. Grace,
00:04:14.819 --> 00:04:17.339
how does a pre -hung door from IAC Acoustics
00:04:17.339 --> 00:04:21.480
compare in the field? Well, they're designed
00:04:21.480 --> 00:04:24.759
to work to meet STC and NIC performance specs.
00:04:25.319 --> 00:04:28.220
In acoustic
Load full transcript
installations, even a small gap or
00:04:28.220 --> 00:04:30.220
misalignment can compromise the performance.
00:04:30.699 --> 00:04:33.620
So that's why it's important that we pre -hang
00:04:33.620 --> 00:04:37.279
and swing our doors ahead of time. Sound is like
00:04:37.279 --> 00:04:40.699
water, so it'll always find a leak. So you have
00:04:40.699 --> 00:04:45.100
to ensure there are none. So since we are an
00:04:45.100 --> 00:04:48.019
acoustics podcast, Mike, can you talk to me a
00:04:48.019 --> 00:04:50.079
little bit about how pre -hung assembly matters
00:04:50.079 --> 00:04:53.819
for acoustic performance? Well, like Grace had
00:04:53.819 --> 00:04:57.800
said, the factory pre -hangs and flings the door
00:04:57.800 --> 00:05:00.680
to make sure that seals are aligned, gaps look
00:05:00.680 --> 00:05:03.060
right. The biggest challenge we find in the field
00:05:03.060 --> 00:05:08.040
is improper rough openings. If the rough opening
00:05:08.040 --> 00:05:12.550
is plumb, true and correct, the pre -hung door
00:05:12.550 --> 00:05:15.230
will literally slide right in, square peg in
00:05:15.230 --> 00:05:19.250
a square hole, and the installation is seamless.
00:05:20.569 --> 00:05:25.209
We find that in our experience, the lack of preparation
00:05:25.209 --> 00:05:28.269
of the opening, whether it's a kit door or whether
00:05:28.269 --> 00:05:30.910
it's a pre -hung, is usually the poison pill
00:05:30.910 --> 00:05:34.189
in the installation. Knowing that IAC prepares
00:05:34.189 --> 00:05:38.529
us for a door that has been factory hung allows
00:05:38.529 --> 00:05:42.329
us to basically... continue without much worry
00:05:42.329 --> 00:05:44.310
about whether or not the door is going to be
00:05:44.310 --> 00:05:47.790
perfect. We have a project with kit doors right
00:05:47.790 --> 00:05:50.089
now that the customers come back to us and said,
00:05:50.250 --> 00:05:54.910
hey, the gap on the door gets wider at the hardware
00:05:54.910 --> 00:05:59.009
and the door is not latching. So these are factory
00:05:59.009 --> 00:06:01.769
installed doors into buildings that we're working
00:06:01.769 --> 00:06:04.089
in. And what we have to do is we have to go back
00:06:04.089 --> 00:06:06.910
into those kit doors, disassemble them completely.
00:06:08.639 --> 00:06:11.279
basically back out the way that they're attached
00:06:11.279 --> 00:06:14.199
to the framing, the rough opening, skim it, and
00:06:14.199 --> 00:06:16.199
then put it all back together. Whereas with IAC,
00:06:16.420 --> 00:06:19.699
the frames usually welded in the situations that
00:06:19.699 --> 00:06:22.839
I'm talking about. We put them in, we level them
00:06:22.839 --> 00:06:25.459
with lasers. Once the laser says it's perfect,
00:06:25.620 --> 00:06:30.300
99 .9 % of the time, the door closes and latches
00:06:30.300 --> 00:06:33.279
perfectly. A lot of times it could be just the
00:06:33.279 --> 00:06:35.199
lasers a little bit, you know, or you're looking
00:06:35.199 --> 00:06:38.259
at it, you know, it's closed. But the thing about
00:06:38.259 --> 00:06:41.079
when IAC sends out the door, once their technicians
00:06:41.079 --> 00:06:43.939
in the factory sign it, it gets the QA sticker.
00:06:44.300 --> 00:06:49.939
We pretty much see that as it being 100%. And
00:06:49.939 --> 00:06:51.939
Grace, is there anything you'd like to add about
00:06:51.939 --> 00:06:54.079
acoustic performance differences between the
00:06:54.079 --> 00:06:58.480
two types of doors? IAC has the ability to...
00:06:59.199 --> 00:07:02.360
go above and beyond the typical expectation of
00:07:02.360 --> 00:07:06.779
STC options on the market. We have an STC61 door
00:07:06.779 --> 00:07:11.160
option as well as an STC64 door option, which
00:07:11.160 --> 00:07:14.279
I don't think there's many of those on the market.
00:07:14.379 --> 00:07:16.439
And I'm not sure if there's any that come as
00:07:16.439 --> 00:07:20.660
a kit. That would be a pretty hefty kit. That's
00:07:20.660 --> 00:07:23.519
correct. I can tell you this. We have a job right
00:07:23.519 --> 00:07:26.980
now with an STC61. And just to give you an idea,
00:07:27.019 --> 00:07:29.639
an STC 51 is a two and a half inch leaf. This
00:07:29.639 --> 00:07:32.660
STC 61 is a five inch leaf. So it's twice the
00:07:32.660 --> 00:07:36.420
thickness. And weight wise, it's about 700 pounds.
00:07:36.879 --> 00:07:40.279
And that's just a standard 307O door. And there's
00:07:40.279 --> 00:07:42.459
a lot of things to consider when you're swinging
00:07:42.459 --> 00:07:44.639
that kind of weight, especially in a 90 degree
00:07:44.639 --> 00:07:48.259
opening to the rough opening. So when we get
00:07:48.259 --> 00:07:50.379
into the big, what we call the big boys, there's
00:07:50.379 --> 00:07:52.220
a lot of pre -planning. There's a lot of stuff
00:07:52.220 --> 00:07:54.490
that we... pushed back on the factory, it has
00:07:54.490 --> 00:07:57.769
to be perfect because to try and set and align
00:07:57.769 --> 00:08:00.949
a 700 -pound door in the field that hasn't been
00:08:00.949 --> 00:08:02.589
pre -hung in the frame or anything, there's a
00:08:02.589 --> 00:08:04.649
lot of stuff that could go absolutely wrong,
00:08:04.769 --> 00:08:10.730
and it has in the past. You know, that's a perfect
00:08:10.730 --> 00:08:13.569
segue for me. I want to jump into a discussion
00:08:13.569 --> 00:08:17.329
about oversized or specialty doors. Grace, do
00:08:17.329 --> 00:08:19.829
you want to kick us off? And then, Mike, maybe
00:08:19.829 --> 00:08:24.579
you can jump in with some thoughts. Sure. Not
00:08:24.579 --> 00:08:27.000
to sound like a mother of ten, but all my doors
00:08:27.000 --> 00:08:31.160
are special, okay? Each is made to order. But
00:08:31.160 --> 00:08:34.820
when it comes to the really big ones or the sliders
00:08:34.820 --> 00:08:38.379
and anything that's super noise lock, they definitely
00:08:38.379 -->
00:08:40.600
have a longer lead time, and I want people to
00:08:40.600 --> 00:08:42.740
be able to note that. So don't wait too long
00:08:42.740 --> 00:08:46.100
to get that quoted or ordered. A lot goes into
00:08:46.100 --> 00:08:49.080
making those things. as you can imagine. So we
00:08:49.080 --> 00:08:51.159
require a lot of information up front in order
00:08:51.159 --> 00:08:53.179
to properly design the best solution for the
00:08:53.179 --> 00:08:56.399
application. But when it comes to, you know,
00:08:56.399 --> 00:08:58.940
more basic oversized doors within our noise lock
00:08:58.940 --> 00:09:02.879
line, think doors over 8 foot but under 16 feet,
00:09:03.039 --> 00:09:06.879
the fire rating is going to be what you want
00:09:06.879 --> 00:09:09.419
to consider. Because for those, you can't actually
00:09:09.419 --> 00:09:13.120
get a UL label for doors over a certain size
00:09:13.120 --> 00:09:16.289
because they simply can't be tested. due to their
00:09:16.289 --> 00:09:19.049
size. Instead, we can provide a UL certificate
00:09:19.049 --> 00:09:21.350
so you can still rest assured that these are
00:09:21.350 --> 00:09:23.809
constructed with life safety guidelines in mind,
00:09:23.929 --> 00:09:27.029
but you won't be able to get an actual label.
00:09:28.549 --> 00:09:31.289
Mike, anything to add about specialty doors or
00:09:31.289 --> 00:09:34.850
just any closing thoughts from the field? So
00:09:34.850 --> 00:09:37.029
in my most recent experience, when you deal with
00:09:37.029 --> 00:09:40.690
oversized doors, they are usually quite heavy,
00:09:40.769 --> 00:09:44.700
not able to be... handled manually by hand or
00:09:44.700 --> 00:09:48.879
set by hand the critical component like i said
00:09:48.879 --> 00:09:51.620
before with most doors is an opening that is
00:09:51.620 --> 00:09:56.460
plumb true and correct meaning it is the threshold
00:09:56.460 --> 00:09:59.600
is level and i mean level within an eighth of
00:09:59.600 --> 00:10:03.460
an inch any variation vertical plumb being out
00:10:03.460 --> 00:10:06.480
of plumb vertically or being out of level horizontally
00:10:06.480 --> 00:10:09.820
will absolutely affect the way the door looks.
00:10:10.259 --> 00:10:14.039
So on oversized doors, it's the onus is on the
00:10:14.039 --> 00:10:17.299
contractor to make sure that he provides the
00:10:17.299 --> 00:10:19.899
install crew, which is us, an opening that is
00:10:19.899 --> 00:10:24.200
flawless. And if it's not flawless, the only
00:10:24.200 --> 00:10:25.820
thing we can guarantee is the door's not going
00:10:25.820 --> 00:10:29.080
to open. Thank you, Mike. Grace, do you have
00:10:29.080 --> 00:10:32.539
any last takeaways for our listeners? Yes, I
00:10:32.539 --> 00:10:35.179
would like to say that. If performance and reliability
00:10:35.179 --> 00:10:38.799
matter, especially for sound isolation, IAC's
00:10:38.799 --> 00:10:42.320
engineered factory pre -hung acoustic doors deliver
00:10:42.320 --> 00:10:45.279
consistency and performance that field -built
00:10:45.279 --> 00:10:48.600
kit doors just can't match. If your door is going
00:10:48.600 --> 00:10:51.240
to be tested after installation, you'll want
00:10:51.240 --> 00:10:54.740
an IAC door in that rough opening. That's just
00:10:54.740 --> 00:10:57.259
about time. Thank you both, and thank you to
00:10:57.259 --> 00:11:00.559
our listeners. For more on IAC Acoustics' architectural
00:11:00.559 --> 00:11:03.600
doors and engineered acoustic systems, visit
00:11:03.600 --> 00:11:05.860
their product pages and specification guides
00:11:05.860 --> 00:11:10.080
at iacacoustics .com. If you enjoyed this conversation,
00:11:10.419 --> 00:11:12.899
be sure to subscribe or share this episode with
00:11:12.899 --> 00:11:14.720
a colleague. Thanks for listening.