TRASCRIZIONE 🔗
WEBVTT
00:00:00.800 --> 00:00:05.919
Welcome back to Measure Matters, the podcast where we dive into all things metrology and calibration.
00:00:06.160 --> 00:00:10.800
I'm your host, Sally Pittman, and today we are back with a brand new guest, Sam Cain.
00:00:11.119 --> 00:00:20.640
Sam is a senior electrical engineer here at Mencer, and today he is here to tell us about all things pressure regulators, how they work, how they differ, and the pros and cons of each type.
00:00:21.280 --> 00:00:23.839
So no need to regulate your patience any longer.
00:00:24.000 --> 00:00:25.440
Let's jump right in.
00:00:26.000 --> 00:00:30.079
You're listening to Measure Matters, a podcast by Mencer.
00:00:31.039 --> 00:00:32.159
Well, hello, Sam.
00:00:32.479 --> 00:00:33.679
Hey, thanks for having me.
00:00:33.920 --> 00:00:35.119
Yes, thank you for joining us.
00:00:35.280 --> 00:00:41.119
So this is your first time on the podcast, but not your first time on our YouTube channel.
00:00:41.359 --> 00:00:41.759
That's true.
00:00:41.920 --> 00:00:44.000
How does it feel to be back in the spotlight today?
00:00:44.240 --> 00:00:45.840
Oh yeah, I'm honored.
00:00:46.159 --> 00:00:48.560
Um, so how long have you been with Mencer?
00:00:49.119 --> 00:00:51.200
Um coming up on 10 years now.
00:00:51.520 --> 00:00:51.840
Wow.
00:00:52.000 --> 00:00:52.320
Yeah.
00:00:52.560 --> 00:00:57.840
And uh I've been in uh the RD department the the entire time.
00:00:58.000 --> 00:01:12.319
So yeah, I've been able to work on a variety of different products within that that time, uh, from transducers uh up to pressure controllers and uh and some other stuff as well.
00:01:12.480 --> 00:01:12.799
So yeah.
00:01:13.040 --> 00:01:13.840
That's so cool.
00:01:14.000 --> 00:01:19.200
Um can you explain a little bit about what you do as a senior electrical engineer?
00:01:19.599 --> 00:01:42.239
Yeah, I mean, um mostly um system design uh for our products as well is the nitty-gritty electronics design, which is the PCBs, um, and then uh firmware development as well, and um, you know, leadership type stuff, uh mentoring uh younger engineers as well.
00:01:42.480 --> 00:01:44.000
So we have a summer intern.
00:01:44.480 --> 00:01:44.799
We do.
00:01:44.959 --> 00:01:48.719
So that's cool that you get to be kind of a uh hands-on for that.
00:01:48.959 --> 00:01:57.680
Yeah, I mean, I I remember when I was uh an intern, rewarding to uh be able to teach somebody and uh you know kind of watch them grow.
00:01:58.000 --> 00:01:58.879
That's so cool.
00:01:59.200 --> 00:02:01.439
Well, we're here to talk about regulators today.
00:02:01.599 --> 00:02:03.840
So I would love to just start with the basics.
00:02:04.000 --> 00:02:06.879
Can you explain what a pressure regulator is?
00:02:07.519 --> 00:02:17.919
Yeah, um, so to use a uh circular definition, um it's a it's a device that regulates pressure.
00:02:18.080 --> 00:02:20.080
And so um what does that mean?
00:02:20.240 --> 00:02:39.599
Um
Load full transcript
it's like um any um energy system, um, like for example, uh a power plant or something kicks out electricity at a really high voltage, and then when it gets to your home, it's been regulated down to some usable uh voltage.
00:02:39.759 --> 00:02:42.719
So a uh pressure regulator is a similar thing.
00:02:42.879 --> 00:02:55.120
You um you have some high, usually starting with a higher pressure, and then uh the the regulator is what steps it down to a usable um uh lower pressure.
00:02:55.520 --> 00:02:55.759
Okay.
00:02:56.000 --> 00:02:56.159
Yeah.
00:02:56.400 --> 00:02:57.039
Okay, cool.
00:02:57.199 --> 00:03:03.360
And I might be getting another circular definition, but on the flip side, can you explain what a pressure controller is?
00:03:03.759 --> 00:03:05.120
Yeah, that's a good question.
00:03:05.199 --> 00:03:12.400
I I think a lot of people um it's they they can be used as um interchangeable terms.
00:03:12.639 --> 00:03:22.080
Um generally, though the way we speak about it here at Mincer is a regulator, is kind of the the heart of the controller.
00:03:22.240 --> 00:03:22.479
Okay.
00:03:22.639 --> 00:03:35.520
Whereas a controller has all the bells and whistles of a display and a touch screen and communication ports and uh some accessory uh electronics or mechanical gadgets.
00:03:35.680 --> 00:03:49.120
Um, so a controller would be like a uh ready-to-use um uh uh you know off-the-shelf device that we sell where the regulators want the core component of uh the controller.
00:03:49.360 --> 00:03:52.000
Okay, so every controller has a regulator.
00:03:52.319 --> 00:03:52.719
Correct.
00:03:52.879 --> 00:03:53.120
Okay.
00:03:53.759 --> 00:03:54.319
Cool.
00:03:54.560 --> 00:03:59.280
Um, so do you have any analogies for pressure regulators?
00:03:59.759 --> 00:04:20.800
Yeah, I mean, uh I talked about one uh being um like uh, you know, I'm I'm an electrical engineer, so of course my mind goes to um, you know, things like transformers or uh uh voltage regulators on a PCB, uh things like uh uh butt converters and uh boost converters or uh low dropout regulators.
00:04:21.360 --> 00:04:28.879
Um but in a in a sense, an electronic uh pressure regulator is a control system.
00:04:29.199 --> 00:04:36.399
And um there, you know, control systems uh are everywhere you look, uh you may just not realize it.
00:04:36.480 --> 00:04:47.519
I mean, uh some common examples are your cruise control on your car, you set it to go 65 miles per hour and it it regulates that uh that uh that speed.
00:04:47.839 --> 00:04:55.519
Or your uh oven in your kitchen, you know, you set it to 400 degrees and it regulates uh the temperature.
00:04:55.680 --> 00:04:57.600
So those are some common ones.
00:04:57.759 --> 00:05:00.720
Um there's yeah, also all sorts of other ones as well.
00:05:00.800 --> 00:05:04.879
But yeah, I think most people can probably uh yeah uh relate to those two.
00:05:05.199 --> 00:05:05.680
So yeah.
00:05:06.160 --> 00:05:13.519
So when you
bring up the example of the oven, I it kind of makes me think like when you set it, it doesn't stop climbing necessarily.
00:05:13.680 --> 00:05:17.519
It kind of regulates itself to try to get to that exact temperature.
00:05:17.920 --> 00:05:18.879
Yeah, exactly.
00:05:18.959 --> 00:05:19.279
Yeah.
00:05:19.439 --> 00:05:31.040
Um, you know, in a in a perfect world, um, you would enter 400 degrees uh, you know, set point, and it would be a perfect step function that would take zero time.
00:05:31.519 --> 00:05:33.680
Um, but yeah, it doesn't happen that way.
00:05:33.759 --> 00:05:36.160
So it's it's kind of a ramp function.
00:05:36.480 --> 00:05:41.040
And then um, if you go over 400, that would be overshoot.
00:05:41.199 --> 00:05:50.079
Um, and then if you uh oscillate around 400, that would be uh stability um uh measurement.
00:05:50.240 --> 00:05:53.600
Um and so a pressure regulator is the same way, you know.
00:05:53.680 --> 00:05:58.160
Uh somebody punches in, I want to control 100 bar.
00:05:58.879 --> 00:06:07.920
Um in an ideal world, it would happen instantaneously, but uh it has to climb up and um it can overshoot.
00:06:08.000 --> 00:06:15.360
And so these are things we have to consider when we're uh uh designing and uh uh yeah, designing a pressure regulator.
00:06:15.839 --> 00:06:16.160
Okay.
00:06:16.399 --> 00:06:24.240
So when it does overshoot, what part of this tells the output, hey, we've gone too far up, we need to come back down a little bit?
00:06:24.560 --> 00:06:35.519
Yeah, so um a core part of a closed loop um control system is uh it has feedback.
00:06:35.759 --> 00:06:49.439
And so um, like in your oven, for example, it'll it'll have a temperature sensor within the oven that knows um, hey, we're at 405 degrees.
00:06:49.600 --> 00:06:52.560
Now we need to turn off the uh heating coil.
00:06:52.720 --> 00:07:23.759
And so a pressure regulator, um, your sensor, if your set point is X number, let's say 100 bar, and we go to 101 bar, the sensor reports back to the regulator, and then the regulator has some out uh some output that drives some electrovo electromechanical uh device to uh try to bring that back down and try not to go below it and you know get exactly to the desired set point.
00:07:23.839 --> 00:07:29.120
Um called stability, trying to get it to that set point?
00:07:29.439 --> 00:07:29.920
Exactly.
00:07:30.000 --> 00:07:30.399
Yeah.
00:07:30.560 --> 00:07:49.519
Um when you're at the set point, um you're never, you know, in digital systems like uh, for example, if we say the pressure regulator to go to 100.00000 bar, it's never exactly, you know, an infinite zeros.
00:07:49.839 --> 00:07:59.199
Uh uh so how closely it it uh wobbles around uh your set point is the control stability.
00:07:59.920 --> 00:08:01.040
Okay, cool.
00:08:01.279 --> 00:08:05.199
Um so there are different types of regulators, is that right?
00:08:05.439 --> 00:08:06.079
That's correct.
00:08:06.240 --> 00:08:06.480
Yep.
00:08:07.680 --> 00:08:10.319
Can you talk a little bit about the different kinds?
00:08:10.720 --> 00:08:16.800
Yeah, so um we have a couple of Vincer's pressure regulators in front of us.
00:08:17.040 --> 00:08:23.600
Um one is the SVR, which stands for solenoid valve regulator.
00:08:23.759 --> 00:08:29.439
Okay, and the other is an NVR, which stands for needle valve regulator.
00:08:29.680 --> 00:08:34.639
And so there's some um pros and cons to each one.
00:08:34.799 --> 00:08:37.519
Um and which one is is this the SVR?
00:08:37.759 --> 00:08:38.879
So this is the SVR.
00:08:39.360 --> 00:08:50.480
Um so a lot of these solenoids are in this uh contraption here, and then the the NVR, um they these are the two needle valve regulators.
00:08:50.720 --> 00:09:07.279
And so both of them you can think about uh essentially there's an orifice, and you have high pressure on one side and a lower pressure on the other side, and uh what we do with that orifice is how you regulate pressure.
00:09:07.440 --> 00:09:19.200
Okay so on a solenoid valve uh regulator, for example, we're opening and closing that orifice very, very quickly to regulate the pressure.
00:09:19.360 --> 00:09:24.399
And on the needle valve, we're essentially controlling the size of the orifice.
00:09:24.480 --> 00:09:29.360
It's the orifice is changing size um from closed to fully open.
00:09:29.600 --> 00:09:37.279
So it's a it's the uh a solenoid valve is a very binary on or off, but you can do it very quickly.
00:09:37.519 --> 00:09:37.840
Okay.
00:09:38.000 --> 00:09:51.279
Um, and then the needle valve is there's a lot of it's all gray area, and you can be uh you can be zero percent zero percent closed, you can be a hundred percent open, you can be thirty-three percent open, uh, etc.
00:09:51.679 --> 00:09:51.840
Okay.
00:09:52.639 --> 00:09:59.039
So I've heard the needle valve um explained kind of like a pencil in like a three-ring piece of paper.
00:09:59.360 --> 00:10:03.440
And it kind of the more you let off, the more pressure gets released.
00:10:03.600 --> 00:10:08.879
Do you have like kind of another analogy that could be used for the uh SVR?
00:10:09.519 --> 00:10:21.360
Yeah, I mean an SVR would be um instead of instead of a pencil on your uh your three-ring hole, um, you could just put a you know a piece of paper over the hole.
00:10:21.519 --> 00:10:27.039
And uh what you're doing is you're moving that paper back and forth very quickly.
00:10:27.200 --> 00:10:42.240
And um, so it it has the same sort of um uh r response where um if it's if it's all the way open, um, then all that pressure from one side is gonna uh flow into the other side.
00:10:42.399 --> 00:10:42.720
Gotcha.
00:10:43.039 --> 00:11:01.200
Um and then if you if you want like the NVR, if you wanted it 50% open, maybe on the SVR, you would have the orifice, the the three-ring hole uh open half the time and closed half the time, so we can have a similar type response.
00:11:01.519 --> 00:11:01.840
Okay.
00:11:02.000 --> 00:11:02.159
Yeah.
00:11:02.559 --> 00:11:10.000
So back to like our oven analogy, I'm assuming if it goes over too much, then it would be the other side that opens to relieve the pressure.
00:11:10.320 --> 00:11:10.879
Yes, exactly.
00:11:11.039 --> 00:11:19.600
So it's like um I I've been mainly talking about uh one orifice, but that would be like the inlet, and then there's an outlet as well.
00:11:19.759 --> 00:11:23.840
So you have like some box or however you want to think about it.
00:11:23.919 --> 00:11:39.360
And you have a small orifice on one side, and uh that's your input, you can control that to go up, and then you have one on the output uh or the outlet, and it is to go down, so you can stabilize on both sides.
00:11:39.759 --> 00:11:40.080
Okay.
00:11:40.799 --> 00:11:46.000
Um, and just out of curiosity, is this entire thing considered a regulator?
00:11:46.159 --> 00:11:48.080
Or would it just be one part of this?
00:11:48.480 --> 00:11:50.159
Uh, that's a great question.
00:11:50.399 --> 00:12:01.120
Um, I think you may get different answers from different people, but um I I would consider, yeah, this this SVR, for example, uh a fully built regulator.
00:12:01.279 --> 00:12:19.120
It, for example, it has um the electromechanical um device for controlling pressure, it has the electronics for driving that, and then it has the the sensor, which is your closed loop feedback, and so the the electronics is what ties this all together.
00:12:19.519 --> 00:12:25.360
And um, so yeah, this would be a full uh control system pressure regulator at this this portion.
00:12:25.519 --> 00:12:33.440
You don't need the accessory uh devices, uh but for to make things uh uh user-friendly, you you would.
00:12:33.759 --> 00:12:36.000
Okay, so this is the guts of a controller.
00:12:36.240 --> 00:12:36.639
Exactly.
00:12:37.039 --> 00:12:38.559
Okay, very cool.
00:12:38.799 --> 00:12:42.159
Um, so you talked about different types.
00:12:42.320 --> 00:12:45.519
Can you go into some of the pros and cons of each type?
00:12:45.919 --> 00:12:48.000
Yeah, that's that's a great question.
00:12:48.240 --> 00:13:00.799
Um so um with a needle valve regulator, uh, this guy here, um your orifice orfices can be a lot bigger.
00:13:01.039 --> 00:13:16.559
Um and also uh you the differential, so you know, back to our box or whatever, the the differential is the pressure difference between the the the one side of it and then the uh within the box.
00:13:16.720 --> 00:13:23.120
The differential can be really great um because of the materials of the the needle valve.
00:13:23.600 --> 00:13:30.320
And so um at high differentials, um pressure moves very quickly.
00:13:30.399 --> 00:13:38.000
You get really high flow rates, and so that means for the user they can control pressure a lot faster.
00:13:38.320 --> 00:13:40.320
Um, so that's that's one benefit.
00:13:40.480 --> 00:13:51.279
The other benefit is um high differentials uh across a SVR would they can be uh detrimental to the lifetime of the product.
00:13:51.440 --> 00:14:03.919
Um so um Mincer's SVR, we actually have to control the differential across the uh solenoid valves, and that has some benefits.
00:14:04.159 --> 00:14:21.360
One is the reliability of the uh the the solenoid valves, they they don't have the full differential, and um but the downside is you have a slower uh your control speed can be slower because of that.
00:14:21.679 --> 00:14:33.039
But um there's also um yeah, I mean as far as control stability, they both can achieve really uh tight uh control stability windows.
00:14:33.600 --> 00:14:41.440
Um but yeah, I mean the the main thing is it's it's a trade-off between speed and um reliability.
00:14:41.759 --> 00:14:42.080
Okay.
00:14:42.559 --> 00:14:46.879
Um can you break down what you mean by differential when you say differential?
00:14:47.120 --> 00:14:50.000
Yeah, yeah, that that can be a weird weird term.
00:14:50.159 --> 00:14:57.120
Um uh, you know, a lot of people think of uh cars or something, uh but uh a differential is just a it's just a difference.
00:14:57.279 --> 00:15:15.440
Um so if we have one needle valve, uh so one orifice, um and it's you know, we're opening and closing that orifice on one side we have let's say 150 bar, and then uh on the other side of the orifice, we have uh zero bar.
00:15:15.840 --> 00:15:19.440
So the differential would be 150 bar.
00:15:19.519 --> 00:15:28.080
Um and then the uh the another example, just to make it clear, if we had kept our 150 bar, but now we're at 50 bar, it would be 100 bar.
00:15:28.639 --> 00:15:29.039
Okay, yeah.
00:15:29.279 --> 00:15:35.840
So when you're saying like some have high differential versus low differential, it's just a higher difference versus a lower difference.
00:15:36.159 --> 00:15:36.960
Yeah, exactly.
00:15:37.039 --> 00:15:37.279
Yeah.
00:15:37.679 --> 00:15:43.200
And um, yeah, I mean, pressure is a highly nonlinear uh system.
00:15:43.679 --> 00:15:49.840
And so that's why at really high differentials, the the flow rate is is really great.
00:15:50.159 --> 00:15:50.480
Okay.
00:15:50.639 --> 00:15:50.799
Yeah.
00:15:51.120 --> 00:15:53.200
So you talked about some different types.
00:15:53.360 --> 00:15:57.679
Um, I want to get into different applications that use the different types.
00:15:57.840 --> 00:16:03.120
Are there any that come to mind um that you think would be better for like an NVR versus an SVR?
00:16:03.440 --> 00:16:05.360
Yeah, good good question.
00:16:05.600 --> 00:16:12.480
Um so uh NVR, um, like one of our products is the CPC 3050.
00:16:12.559 --> 00:16:24.480
Um it uses uh needle valve regulators, and um it it's a good application for it would be um high volume sensor manufacturing.
00:16:24.639 --> 00:16:39.200
So if some company is making thousands of sensors uh, you know, a day or you know, even an hour, they have to have some device control the pressure on those sensors to verify them.
00:16:39.679 --> 00:16:45.440
And so it's like um, you know, time is money, they would need to control those points very quickly.
00:16:45.679 --> 00:16:52.799
Um whereas an SVR 6050 style regulator may not be able to reach those speeds.
00:16:53.600 --> 00:17:16.799
But um, on the other hand, an SVR, some good applications would be um uh calibration labs, maybe throughput isn't as high volume, and um or uh the applications where reliability over you know 10 or 20 years is is really critical.
00:17:17.039 --> 00:17:23.119
Um that would be a good application for uh like a 60-50 style SVR regulator.
00:17:23.440 --> 00:17:30.400
Okay, so kind of just balancing like efficiency of like maybe production versus like the accuracy you might need.
00:17:30.799 --> 00:17:31.119
Exactly.
00:17:31.279 --> 00:17:32.799
Okay, very cool.
00:17:33.119 --> 00:17:37.920
So how do regulators factor into the whole system of the controller?
00:17:38.000 --> 00:17:43.119
I know it's the guts, but can you explain a little bit more about where it really fits into the controllers?
00:17:43.519 --> 00:17:50.720
Yeah, I mean, um, well, like you said, I mean, it's it's the the heart of the the controller.
00:17:50.960 --> 00:18:05.599
Um, you know, uh uh we could design all the coolest bells and whistles imaginable on on a controller, um, but nobody's gonna care if the regulator doesn't work properly.
00:18:05.839 --> 00:18:06.160
Right.
00:18:06.319 --> 00:18:11.039
Um so yeah, uh maybe I uh yeah.
00:18:11.680 --> 00:18:12.880
No, that makes sense.
00:18:13.200 --> 00:18:17.519
Well, um I think those are all the questions that I have for you today, Sam.
00:18:17.680 --> 00:18:19.359
Thank you so much for joining us.
00:18:19.680 --> 00:18:20.960
Yeah, thanks for having me.
00:18:21.119 --> 00:18:23.599
Uh I hope uh everybody learned something.
00:18:25.200 --> 00:18:26.240
Thank you for joining us.
00:18:26.400 --> 00:18:28.000
We hope you enjoyed today's podcast.
00:18:28.400 --> 00:18:33.200
To listen to more topics, you can visit info.mencer.com forward slash podcast.
00:18:33.440 --> 00:18:39.519
And if there's a topic you're interested in hearing, you can visit any of our social platforms or leave a comment down below this video.
00:18:40.160 --> 00:18:43.920
From all of us here at Mencer, you stay classy metrology lovers.