00:00:00.160 --> 00:00:08.080
We're also showing them that it can cost them less by properly designing and selecting equipment and properly designing systems.
00:00:08.160 --> 00:00:15.279
If the fan speed's wrong, the static pressures are wrong, the refrigerant charge is wrong, the air to room-to-room air balance is wrong.
00:00:15.439 --> 00:00:24.960
If if those things don't get added in at the end to validate everything else that happened before, you're not going to get the value out of the operation out of the system.
00:00:34.640 --> 00:00:40.799
Hey everybody, welcome to another episode of HVAC ADHD venting with the pros.
00:00:41.280 --> 00:00:48.880
I'm here today with Matthew Cooper from PEG, and we're going to talk about HVAC design and where the industry could improve.
00:00:49.200 --> 00:00:52.479
Before we do that, I'm going to let Matt introduce himself real quick and then we'll get going.
00:00:52.640 --> 00:00:53.359
Matt, take it away.
00:00:53.600 --> 00:00:54.079
I appreciate that.
00:00:54.159 --> 00:00:54.719
Thanks, Jeremy.
00:00:54.960 --> 00:00:59.039
I'm Matthew Cooper, Senior Vice President, Chief Operating Officer at BEG.
00:00:59.200 --> 00:01:05.200
We are a full service ResNet HERS rating company inspecting and testing about 55,000 homes a year.
00:01:05.280 --> 00:01:10.000
We're also licensed mechanical electrical plumbing design engineers licensed in all 50 states.
00:01:10.079 --> 00:01:14.000
And we have about 100,000 homes a year built with our HVAC designs.
00:01:14.159 --> 00:01:18.480
We also have a third-party commercial inspection division of the company.
00:01:18.640 --> 00:01:30.879
And then the fourth part of the company is independent third-party product testing division called Empirical Solutions, where we provide third-party analysis of building materials that manufacturers are looking to have validated.
00:01:30.959 --> 00:01:32.799
So those are the four main parts of the company.
00:01:33.040 --> 00:01:34.480
Well, that's cool that we were just talking.
00:01:34.560 --> 00:01:37.200
I didn't even know you guys were in the commercial space like that.
00:01:37.280 --> 00:01:38.239
So that's pretty cool.
00:01:38.400 --> 00:01:51.920
And one of the things that we sort of touched on off-camera was the fact of the raider industry or the raider world, there being these different little add-ons where if you're looking just a little bit adjacent to where you're at, you can branch out and maybe make a little bit more money.
00:01:52.000 --> 00:01:56.319
So I like to see that you guys have fully taken care of that or taken advantage of that opportunity.
00:01:56.560 --> 00:02:09.039
Yeah, there's a lot of ancillary things, Jeremy, that I think that the raiding community, either based on their own personal experience or just their level of comfort, are missing out on the opportunity to add on to their business model.
00:02:09.199 --> 00:02:12.159
There's so many different areas of opportunity out there.
00:02:12.319 --> 00:02:19.599
HVAC design obviously is a big one that we'll focus on today for the most part, but there's even others out there besides the commercial world.
00:02:19.759 --> 00:02:27.120
We got into the product valuation space, and really that's just from being proficient with the modeling software that's available out there.
00:02:27.280 --> 00:02:32.400
And that's led to us getting involved in the development of tools for embodied carbon.
00:02:32.479 --> 00:02:33.680
It leads to more things.
00:02:33.919 --> 00:02:50.479
Another big area of opportunity out there is expert witness and forensics, getting involved in building failures, whether it's residential, institutional, commercial, but having the ability to take the skill set you have, the tools that you've already invested in, and find new ways to use them as a business opportunity.
00:02:50.719 --> 00:02:51.120
Absolutely.
00:02:51.280 --> 00:02:54.960
So, like you said, we're going to dig into the residential design side of it today.
00:02:55.199 --> 00:03:00.560
To get the conversation started, let's just have you list a few challenges that you readily identify.
00:03:00.800 --> 00:03:04.240
You guys are doing, like you said, 100,000 buildings built to your design.
00:03:04.400 --> 00:03:19.199
So you have a lot of inside information on what is going on in the industry as far as the challenges that we see on an industry-wide basis, maybe not specific to this designer or that designer or this company or that company, but true industry challenges.
00:03:19.360 --> 00:03:20.400
What's your thoughts on that?
00:03:20.479 --> 00:03:22.960
Like where are we at right now with the design fug?
00:03:23.280 --> 00:03:34.479
The biggest limitation that we see consistently is that the home building industry just continues to rely on the contractors that are installing the equipment to do their own designs.
00:03:34.719 --> 00:03:38.960
And the challenge that presents is that they all do it differently.
00:03:39.120 --> 00:04:12.879
And they don't typically tend to follow all the best practices as far as how to use manual J, how to use manual S, how to use Manual D, how to evaluate the differences in the materials that are available in different markets, how to take advantage of nuances of the detailed components of those software programs, whether it's WriteSoft or Write Draw or others that are out there, that getting beyond just the use of default settings and really being able to dig into the performance tables for the equipment that is being installed.
00:04:12.960 --> 00:04:22.879
I mean, you've got builders out there investing heavily into better equipment to try and manage challenges with moisture and latent cooling, et cetera.
00:04:23.040 --> 00:04:33.439
And the contractors are essentially voiding that investment too frequently by not applying the actual performance criteria for the equipment itself.
00:04:33.600 --> 00:04:51.279
And so then you end up with
Load full transcript
expensive variable speed, variable flow equipment out there that the value proposition of what the builder thinks they're buying is getting diluted, if not completely diminished by not properly taking advantage of how that equipment can perform.
00:04:51.519 --> 00:05:04.560
Yeah, and it ends up being oversized to the maximum, and then they want the turn down of the variable speed to take care of it, and then it basically robs the customer of any of the value of the actual turndown of the variable speed.
00:05:04.720 --> 00:05:08.720
Is that what you guys are seeing a lot of, or that you help prevent a lot of?
00:05:09.120 --> 00:05:14.399
Yeah, so typically we get engaged at a couple different levels for a lot of large nationals.
00:05:14.560 --> 00:05:21.360
We can engage at the corporate level to kind of come in and audit in different markets across the country what their contractors are doing.
00:05:21.600 --> 00:05:32.160
So we'll identify in most markets an average of a half ton or up to a ton and a half of oversizing, pretty standard across the industry.
00:05:32.399 --> 00:06:04.720
And some of that just done unintentionally, just the blanket application of default values, and others done fairly intentionally, manipulating the weather data source for temperature references so that they can intentionally try to inflate the size of the equipment to selecting options that are not even in the home, all in an effort to try often to have that oversizing take place so that it can mask some of the limitations of the quality of the install.
00:06:04.959 --> 00:06:09.920
How much of that do you think is caused by or is being prevented by code officials?
00:06:10.079 --> 00:06:22.399
Because we're in a weird space where the older code officials that were in the market are starting to phase out and there's some younger guys coming in and they know a little bit more about manual J, manual S, this type of stuff than the younger crowd did.
00:06:22.480 --> 00:06:25.839
They're hearing about it a lot more, but I still see so random.
00:06:25.920 --> 00:06:29.199
It's like some stuff will be they don't ever look at it, they just file it.
00:06:29.279 --> 00:06:34.240
And then on the other end of the spectrum, I have some guys getting dinged for stuff that is not even really a failure.
00:06:34.399 --> 00:06:38.079
Those guys just don't understand the manual J or manual S selection process.
00:06:38.240 --> 00:06:42.639
Are you seeing, yeah, I know you guys deal with, especially on the production side, a ton of code officials.
00:06:42.720 --> 00:06:44.639
So I was wondering what you guys are seeing there.
00:06:44.959 --> 00:06:46.079
It's really inconsistent.
00:06:46.160 --> 00:07:00.639
Like you said, there are still a lot of markets that the code official will accept a worst case orientation manual J, and they'll just do one for the entire community, or they'll do one by model type for the entire community, almost like a master plan.
00:07:00.800 -->
00:07:12.399
There's other municipalities that could be literally 20 minutes away that are looking for a PE stamped lot specific manual J, manual S, and in some cases a manual D.
00:07:12.959 --> 00:07:15.360
And it it really just varies by the location.
00:07:15.519 --> 00:07:20.720
It's interesting the perspective of is it changing by kind of the age and experience level?
00:07:20.879 --> 00:07:32.319
I haven't really thought about it from that perspective, but we know in every state which municipalities have somebody in the approval process that is looking at them.
00:07:32.399 --> 00:07:34.639
And we know which ones are not looking at them.
00:07:34.879 --> 00:07:38.639
Yeah, yeah, it's unfortunate, but I think that is still a driver of it.
00:07:38.879 --> 00:07:43.680
It often tends to follow also the market regional characteristics.
00:07:43.839 --> 00:07:54.720
So it could be either if it's a state that is progressively following energy code, then we tend to find that more code officials in that state do pay attention to them.
00:07:54.879 --> 00:08:05.279
Or a market where there's like Florida or Houston, for example, where there's a lot of lawsuits out there and a lot of unhappy customers out there because of moisture issues in their homes.
00:08:05.439 --> 00:08:10.160
So we tend to see that in those types of markets, code officials pay more attention to it.
00:08:10.319 --> 00:08:21.839
But then you go to a fairly benign market, say Charlotte, North Carolina, code officials aren't looking at them unless it's a specific code official in one municipality that just happens to have an interest in it.
00:08:22.079 --> 00:08:27.519
How much of, or if any, do you see that trickle down, like that enforcement trickle down to the duck systems?
00:08:27.680 --> 00:08:33.600
Because like police and sizing and equipment's one thing, but I rarely ever see them say anything about a bad duck system.
00:08:33.679 --> 00:08:37.120
And I don't know how much of that you've experienced, but like that is one thing.
00:08:37.279 --> 00:08:42.240
I barely see these guys tip their toe in a lot of times, and I feel like they should a lot more.
00:08:42.559 --> 00:09:03.840
The only time I think that we typically will see a code official say something about duck locations or duck quality of duck systems, is if the manual J says something like, you know, 90% of the system is inside the thermal envelope, and they come out and they can clearly see that far more than 10% of the duct system is outside the thermal envelope, and then they'll question it.
00:09:04.000 --> 00:09:19.440
That's a big one for us too, is part of the things that we're promoting with our builder clients is compact design and trying to pull as much as possible inside the thermal envelope so that we don't have the duct system picking up load unnecessarily.
00:09:19.600 --> 00:09:25.840
And that's something that we get a lot of pushback on from HVAC contractors, is they want to do what they want
to do.
00:09:25.919 --> 00:09:33.519
And often it's what's easiest for them is to move as much as possible outside the thermal envelope, just put it in the attic, put it in a crawl space.
00:09:33.600 --> 00:09:34.960
And builders are the same way too.
00:09:35.120 --> 00:09:40.480
They don't want to give up square footage, which we get, but there's so many creative ways to do both.
00:09:40.639 --> 00:09:49.919
There's so many ways to design a system that you can get as much as possible inside the thermal envelope without bulkheads and without giving up square footage.
00:09:50.159 --> 00:09:56.000
And I think that it's a corny phrase, but I think it's a paradigm shift that really needs to take place.
00:09:56.159 --> 00:10:28.399
And where we're finding success, I think, is showing builders the value proposition, that this is not just about better performance, better comfort, maximizing the investment they're making on better equipment, but we're also showing them that it can cost them less by properly designing and selecting equipment and properly designing systems, that by making systems smaller but using specific long throw curved blade registers, we can get a system to cost less for materials.
00:10:28.720 --> 00:10:33.519
It can be easier and faster to install, and it results in smaller equipment.
00:10:33.679 --> 00:10:40.080
So you've got contractors out there that have invested in their own sheet metal shop and they want to sell sheet metal.
00:10:40.240 --> 00:10:54.159
And I get that, but it often isn't really the best solution for the builder or ultimately the homeowner when we could put in a smaller system that has less ductwork, which is offering less resistance now that the fan has to overcome.
00:10:54.320 --> 00:10:57.919
We can specify a smaller system and that saves the builder money.
00:10:58.159 --> 00:11:06.080
There really is an opportunity for a win-win-win, but the HAC industry at large is really where we get the most pushback.
00:11:06.320 --> 00:11:07.919
So let's talk about what you're doing.
00:11:08.080 --> 00:11:09.279
How are you guys achieving that?
00:11:09.440 --> 00:11:10.639
The compact system.
00:11:10.879 --> 00:11:12.720
We're talking typical size house, right?
00:11:12.799 --> 00:11:15.759
Like a typical production size house, just for the context of the audience.
00:11:15.840 --> 00:11:19.679
Like it's not a smaller house, so that's not how you're achieving the compact system.
00:11:19.759 --> 00:11:22.399
So, what is your design strategy to achieve that?
00:11:22.720 --> 00:11:36.480
So, by approaching it from the perspective of we want to make the system as small as possible, yet have it be able to effectively heat, cool, and maintain comfort, that means we need to get still get air mixing into all the spaces.
00:11:36.639 --> 00:11:44.240
So saving cost and time and materials by pulling back from the perimeter, stop washing windows.
00:11:44.320 --> 00:11:46.000
We don't need to wash windows anymore.
00:11:46.240 --> 00:11:46.480
Amen.
00:11:46.799 --> 00:11:49.919
It's an aged strategy that is unnecessary.
00:11:50.080 --> 00:12:10.639
So if we think about the system from the perspective of we just need to get the right amount of air to mix in the room, and we don't need to worry about the perimeter, we don't need to worry about the windows, we don't need to worry about the exterior walls, then we can think from the act of getting the registers, high wall registers back at the core of the house.
00:12:10.799 --> 00:12:19.360
So we're pulling the system as far as we can into the middle of the house, which pulls out duct system components from outside the thermal envelope.
00:12:19.440 --> 00:12:34.799
And then by using high wall curved blade long throw registers, that way we also eliminate the problem of what creates a lot of callbacks in a traditional perimeter system, is people can easily access the homeowner, can easily access the registers.
00:12:34.960 --> 00:12:43.679
So either they close them because they think that it's going to save them money, or furniture gets placed over top of them and it occludes airflow.
00:12:43.840 --> 00:12:48.320
So there's a lot of ancillary benefits to going to that compact system design.
00:12:48.559 --> 00:12:50.159
We get the proper air mixing.
00:12:50.320 --> 00:12:54.240
Granted, we do have to specify specific products.
00:12:54.399 --> 00:13:00.639
So we may have to specify a specific type of register or model number by manufacturers or equal.
00:13:00.879 --> 00:13:08.559
And from a responsibility perspective as a designer, we do have to make sure that those products are available in the market that we're designing for.
00:13:08.799 --> 00:13:16.000
Because that also becomes a point where it doesn't matter if we design a fantastic system and select the proper equipment.
00:13:16.080 --> 00:13:24.720
If the contractor says, Oh, I can't get that product, I can't get seven-inch flex, or I can't get that type of register, then they're going to do what they want to do anyway.
00:13:24.799 --> 00:13:25.919
And the builder's just wasted.
00:13:26.399 --> 00:13:32.639
Yeah, it's an excuse at that point to go ahead and just pivot and do something probably more drastic than even necessary to replace that problem.
00:13:32.960 --> 00:13:36.320
Like a typical bedroom, if you're doing that strategy, where's the register go?
00:13:36.559 --> 00:13:38.320
Just out of curiosity, where are you guys putting it?
00:13:38.559 --> 00:13:41.600
So typically we're looking at ensuring that we're not short cycling.
00:13:41.679 --> 00:13:48.960
So we want the register to be on an interior wall, perhaps from the location of where the door is coming into the bedroom.
00:13:49.120 --> 00:13:55.759
And then we want to have a return location that is not in the direct air distribution path of that supply register.
00:13:55.840 --> 00:14:07.360
Yeah, we do prefer duct all bedroom returns whenever possible, just because from a design perspective and an engineering perspective, I think it provides a better opportunity for consistent comfort.
00:14:07.519 --> 00:14:26.559
But if the builder they just want to do jump ducks or they just want to do transfers, then we just have to ensure that when we do the design and whenever possible, we're trying to do design in AutoCAD or Revit so that we can do clash detection and make sure that where we're saying we want the register and the ducts to go, that they can actually go there.
00:14:26.720 --> 00:14:40.240
Because a quick path to not having the design followed is if you don't do any sort of clash detection, even at just a high level of overlaying truss layouts in your manual D, then the builders or the installing contractor is not going to follow it anyway.
00:14:40.480 --> 00:14:53.039
That's typically where we're looking is to have that air being put in from one angle of the room and the pathway out to be opposite of the direct airflow of the supply so that we don't short cycle the room.
00:14:53.360 --> 00:14:55.919
I just want to back up the one thing you said about the transfer grills.
00:14:56.080 --> 00:15:00.799
Do you think that there's a noticeable comfort difference if transfer grills are used correctly?
00:15:00.960 --> 00:15:13.840
I've always put it more of like a privacy concern than a direct comfort issue, but I'm curious as to if you have like information about or just even anecdotal information about the comfort difference between transfer versus direct return.
00:15:14.080 --> 00:15:21.279
Yeah, I would say anecdotally, transfers are probably the least successful method of getting return airpath to be complete.
00:15:21.440 --> 00:15:26.799
Jump ducks, I think, are a little bit better than transfers and provide a little bit more privacy, as you said.
00:15:26.960 --> 00:15:31.200
But adductive return is always going to be since it can be sized properly.
00:15:31.360 --> 00:15:37.759
I mean, transfers and jump ducks have to be sized properly as well, but they're still reliant on house pressure.
00:15:38.000 --> 00:15:46.960
So where adductive return, as long as the system is on, it's going to overcome the resistance of whatever else is taking place in the house.
00:15:47.120 --> 00:16:14.320
So the reality of a system functioning properly, if doors in the house are getting closed and or other human activities are taking place where you've got dryers running that are pulling a ton of air out of a house, or you've got kitchen exhaust or bath exhaust, anything that's changing the pressure dynamics of the home, even wind, you start to get enough of wind against the outside of the house, it starts to change the zation or stack effect of a home depending on the height.
00:16:14.559 --> 00:16:15.600
It's interesting, Jeremy.
00:16:15.679 --> 00:16:32.159
We're seeing now that particularly in more populated areas of the country that also then tend to have more expensive land, builders are going more and more to
four-story products because they the projects don't pencil out unless they can get the density onto the Yeah, we definitely have that multifamily.
00:16:32.240 --> 00:16:35.919
Everything I've done in the South in the past years had a four-floor on it for sure.
00:16:37.279 --> 00:16:40.240
So the result of that is that we're seeing more stack effect.
00:16:40.399 --> 00:16:47.840
We did for probably the better part of the 2000s when everything was there was a lot more ranch style and just two-story stuff going on.
00:16:47.919 --> 00:16:54.720
And now there's so much townhouse two over two product out there that we're seeing stack effect become more prevalent than it used to.
00:16:54.879 --> 00:16:56.480
Yeah, I never even considered that.
00:16:56.559 --> 00:16:58.159
It's super interesting about that.
00:16:58.240 --> 00:16:59.840
I mean, your four-floor point is correct.
00:17:00.000 --> 00:17:08.559
Even the single family homes that we see being built often have a four-floor with some kind of like little party area that leads out to a terrace or something like that, too.
00:17:08.720 --> 00:17:10.640
So there is a lot of that going on.
00:17:10.880 --> 00:17:13.200
I guess residentially, four stories is four stories.
00:17:13.359 --> 00:17:14.160
It doesn't really matter.
00:17:14.240 --> 00:17:19.759
So you're gonna see that anywhere there is a four-floor be a potential driver to put doctor return into the room.
00:17:20.000 --> 00:17:20.240
Huh.
00:17:20.400 --> 00:17:21.039
That's interesting.
00:17:21.119 --> 00:17:23.519
That was not something I had previously thought about.
00:17:23.759 --> 00:17:27.839
Well, once you get to a four-story town or a two over two, then you're under IBC.
00:17:28.000 --> 00:17:33.119
So it's changing the requirements anyway for what has to be designed, what has to be stamped.
00:17:33.279 --> 00:17:37.440
If you start to think about that walkable roof product, obviously that's appealing to people.
00:17:37.680 --> 00:17:44.079
But when you start to, in the shoulder seasons, leave that door open, it drastically changes the dynamics of that building.
00:17:44.240 --> 00:18:00.559
And gets back to like we talked earlier about commercial inspections and opportunities beyond just the HVAC side of things and the energy performance side of things, but those products start to really maximize the value proposition and the importance of properly inspecting fire barriers and smoke barriers.
00:18:00.720 --> 00:18:13.440
So those are other areas that the rating community can get themselves accredited and certified to be able to inspect the dose of fire and life safety assemblies that become so much more important in attached product and stacked products.
00:18:13.680 --> 00:18:15.359
Yeah, no, that's a great add-on there.
00:18:15.599 --> 00:18:17.279
That's another one I had not even really considered.
00:18:17.359 --> 00:18:18.559
That's completely awesome.
00:18:18.799 --> 00:18:20.079
This is one thing I wanted to ask you.
00:18:20.160 --> 00:18:23.920
Do you have any uh designs where you were just like, I don't know what's going on here?
00:18:24.000 --> 00:18:26.319
Like we did everything right, but we're still having problems.
00:18:26.400 --> 00:18:27.839
It seems like it's installed, okay.
00:18:27.920 --> 00:18:30.799
Like, you got any baffling ones you want to talk about real quick?
00:18:31.200 --> 00:18:32.480
We get baffling ones.
00:18:32.799 --> 00:18:38.960
Challenge often becomes the equipment side of things and not necessarily the install side of things.
00:18:39.119 --> 00:18:41.599
There are some install challenges that we see.
00:18:41.759 --> 00:18:46.400
Contractors that maybe are doing something like a RIA system and they've never done one before.
00:18:46.720 --> 00:18:56.079
And the size of the return or the location of the return didn't follow the design, and that creates significant challenges to that type of system.
00:18:56.400 --> 00:19:02.559
Or contractors that they just want to use one giant return and hope that everything is going to make its way back to it.
00:19:02.640 --> 00:19:05.599
And just in reality, that's not probable.
00:19:05.839 --> 00:19:11.359
So we definitely see more technology changes impacting system designs.
00:19:11.519 --> 00:19:14.720
But really, I think the biggest thing is H3AC grading.
00:19:14.880 --> 00:19:26.400
If you don't close the loop of good design, good equipment selection, good installation, and you don't close the loop with good testing, inspection, and validation, then the best design in the world may not function properly.
00:19:26.480 --> 00:19:33.680
If the fan speed's wrong, static pressures are wrong, the refrigerant charge is wrong, the air to room-to-room air balance is wrong.
00:19:34.000 --> 00:19:42.880
If those things don't get added in at the end to validate everything else that happened before, you're not going to get the value out and the operation out of the system.
00:19:43.200 --> 00:19:44.480
Yeah, I'm so glad you brought that up.
00:19:44.720 --> 00:19:49.759
If you don't get verified, if your system is not verified at the end, you really don't know what's going on out there.
00:19:50.000 --> 00:19:52.160
So how many gradings have you guys done now?
00:19:52.319 --> 00:19:55.680
Just as many installs are you doing on every single design that you do now?
00:19:56.000 --> 00:19:58.799
We do HVAC grading on the majority of our homes.
00:19:58.960 --> 00:20:04.799
That's been a part of the process of overcoming contractor resistance to third-party design.
00:20:04.960 --> 00:20:20.720
Is essentially we'll tell the builder if we're going to do the design, we're going to do the lot specific JS, we're going to do the inspections and testing, including HVAC grading, then if there is a comfort complaint in the home, then we get called first, not the contractor.
00:20:20.880 --> 00:20:26.400
And we will come out and verify that nothing has changed since we left the house
fully commissioned.
00:20:26.640 --> 00:20:33.119
And if we can then verify that it is an actual equipment failure item, then the contractor gets called.
00:20:33.279 --> 00:20:39.759
And that has been successful for us in overcoming that argument that contractors, that's the first thing they'll say.
00:20:40.000 --> 00:20:43.200
If I don't get to size and select the equipment, I'm not warrantying it.
00:20:43.359 --> 00:20:49.680
And so that's been the most successful way for us to overcome that argument is that we'll be the first to come out if there's a comfort complaint.
00:20:50.000 --> 00:20:50.640
That's the same.
00:20:50.720 --> 00:20:59.440
That's the exact reason we created the verified program that we have now is because we're not going to take responsibility for something that we don't know what happened after it left our hands.
00:20:59.599 --> 00:21:00.079
You know what I mean?
00:21:00.160 --> 00:21:09.599
But if you let us prove, either have the contractors demand that they use Measure Quick or some other way of verification and get us their commissioning data that we asked for.
00:21:09.759 --> 00:21:16.799
We have a very specific sheet of information that we want back from them, or just participate in our verified program and it's going to flow back to us naturally.
00:21:16.880 --> 00:21:23.200
But either way, make sure that the system commissioning is verified somewhere so that we have that to go back to.
00:21:23.279 --> 00:21:28.720
And like you said, then we can be the first person to get the call and we can help you understand what it is or isn't.
00:21:28.799 --> 00:21:30.160
And then from there we know where to go.
00:21:30.400 --> 00:21:31.039
So I love it.
00:21:31.119 --> 00:21:32.400
That is the right methodology for sure.
00:21:32.640 --> 00:21:38.720
And we also, as part of our process, we're also registering the HAC equipment for extended warranties.
00:21:39.039 --> 00:21:44.000
So that really helps us close the door on any misstep in the process.
00:21:44.160 --> 00:21:58.319
And one of the things that we're starting to see is the manufacturers' OEMs are actually, if they know that a third party is doing all these checks and balances, they're offering even better warranty terms and conditions to those builders for their equipment.
00:21:58.640 --> 00:22:02.960
I need to get some information from you about that because that's super interesting to me.
00:22:03.119 --> 00:22:06.400
That's something that I thought should be happening, but I wasn't aware that it was happening.
00:22:06.480 --> 00:22:07.200
So that's pretty cool.
00:22:07.359 --> 00:22:08.640
I would like to hear more about that.
00:22:08.880 --> 00:22:09.200
Absolutely.
00:22:09.440 --> 00:22:09.680
Cool.
00:22:09.759 --> 00:22:09.920
Okay.
00:22:10.079 --> 00:22:11.519
I guess we're running up on our time here.
00:22:11.759 --> 00:22:14.880
You're actually my first extended venting with the pros guest.
00:22:14.960 --> 00:22:18.240
I had Joe Madash when we kicked it off, and then you were the very first one.
00:22:18.319 --> 00:22:19.200
So that's very cool.
00:22:19.440 --> 00:22:20.799
Thank you very much for coming on.
00:22:20.960 --> 00:22:28.960
I know you and I try to keep in contact as much as we can for the busy guys that we are, but appreciate it and looking forward to seeing you at a conference here coming up soon.
00:22:29.200 --> 00:22:29.519
Absolutely.
00:22:29.680 --> 00:22:30.640
Looking forward to it as well.
00:22:30.799 --> 00:22:31.359
All right, man.
00:22:31.519 --> 00:22:32.240
Have a good day, man.
00:22:32.319 --> 00:22:32.640
Thank you.
00:22:32.799 --> 00:22:33.119
Thank you for